Gallery · geotechnical model

Examples ready to run
Open them, run them, change them.

Each example is a complete model — layers, structures, water and construction stages — taken from the solver's validation benchmarks. The drawings below are generated from the model file. Open one in a click, run it, then change it for your own project.

15models ready to run
7with the result checked in an article
0software to install
01 / EXAMPLES

Pick a model and open it in one click

  • Soil layers
  • Walls, anchors, geogrids
  • Excavated in a stage
  • Water
Elastic column

Elastic column

Settlement under self-weight; reference γH²/(2·E_oed)

Footing on clay (Prandtl)

Footing on clay (Prandtl)

Pushed to failure; reference (2+π)·c_u

Cantilever excavation

Cantilever excavation

12 m wall, 4 m excavation, Hostun sand

Temporarily suspended
Excavation with an inclined strut

Excavation with an inclined strut

As the previous one, plus a strut after the first step

Temporarily suspended
Berlin excavation, anchored

Berlin excavation, anchored

Schweiger 2002: prestressed ground anchors and dewatering, 13 stages

Published result Ground behind the wall: Mohr-Coulomb +55.5 mm (heave), Hardening Soil −16.0 mm (settlement); wall 29.0 mm with Hardening Soil (source)

Temporarily suspendedRead the article →
Reinforced soil wall

Reinforced soil wall

Geogrids (tension only), FHWA method

⚠ Result at tolerance 1e-2. At stricter tolerances the “released” stage does not converge, and the c–φ reduction finds no stable step above F = 1.0. Do not use this example as proof of a stability margin.

Pile with contact (axisymmetric)

Pile with contact (axisymmetric)

Concrete column in sand, contact R = 0.67, load on the head; N(z) in the results

Published result The pile head settles 1.53 mm under 113 kN (source)

Slope stability

Slope stability

2:1 slope, c′ = 10 kPa, φ′ = 20° (Griffiths & Lane 1999): safety factor and failure mechanism

Published result F = 1.356, against 1.4 published (Griffiths & Lane 1999) (source)

Slope with a lake in front

Slope with a lake in front

The same slope with water 3 m above the toe, in the slope and in the lake (G&L 1999 ex. 5): the lake pushes the face — the worst case

Published result With the lake 3 m above the toe, F drops to 1.277 (source)

Earth dam with a lake

Earth dam with a lake

The Torres & Coffman dam (G&L 1999 ex. 6): lake at 17.1 m, free surface down to the downstream toe; F on the downstream face

Dam without a drain — pore pressures from flow

Dam without a drain — pore pressures from flow

The same dam, pore pressures from steady-state flow: the water exits on the downstream face (seepage face), F ≈ 1.64 against 1.81 with a drain

Slope — ULS check (EN 1997-1)

Slope — ULS check (EN 1997-1)

The 2:1 slope with 20 kPa traffic on the crest (variable action): DA1-C2 / DA3 per SR EN 1997-1/NB, F_d ≥ 1.0

Horseshoe tunnel across two layers

Horseshoe tunnel across two layers

Clay over sand, 6 × 5.5 m tunnel excavated with a support pressure (β method), then lined; V_L and N in the lining

Published result Volume loss V_L = 0.19 % at the end (source)

Circular footing on clay (axisymmetric)

Circular footing on clay (axisymmetric)

Rigid 3 m plate on undrained clay: elastic settlement πqa(1−ν²)/(2E), then pushed to failure; reference 6.05·c_u

Published result Bearing capacity 6.097·c_u, against 6.05·c_u (Eason & Shield 1960): +0.78 % (source)

02 / YOUR OWN MODEL

Already have a model?

Load the .json file saved from the geotechnical model: see its drawing here and open it in one click.

Blank model
03 / QUESTIONS

Frequently asked questions

Can I run a staged excavation analysis in the browser?

Yes. In the JointLib geotechnical model you define the soil layers, the wall, struts or anchors and the water, then the construction stages (excavation, installation, dewatering), and run the finite element analysis from the browser, with nothing to install. The braced excavation above opens ready-made.

Are the example results checked?

Where an example has an article, the article compares the result with an analytical solution or a published benchmark and states the deviation; the card shows that figure and links to it. The solver as a whole is covered by 865 automated checks (census of 9 Nov 2026), listed publicly.

Can I change an example for my own project?

Yes. An example opens as an ordinary model: change the geometry, the layers and their parameters, the structures or the stages, then run it again.

What does it cost?

Running a model needs a free account. Runs are free and unlimited, with no card.

Start from an example

Start from an example or from scratch. Every Studio program is free, with no limit on runs.

An unhandled error has occurred. Reload 🗙