This is the full design page for an isolated footing — from ground pressures through reinforcement to the construction drawing. Unlike calculators that return a single check, here the whole design chain of a column footing is carried out:
- Ground pressures — the contact distribution under the footing, with the ground checks of EN 1997-1
- Footing reinforcement — in bending, from the moment in the footing cantilever (EN 1992)
- Pedestal reinforcement — the connection to the column
- Punching shear — the check of the slab against being punched by the column (EN 1992 §6.4)
- Word calculation brief and DXF drawing — the final deliverables
Ground checks (EN 1997-1)
The pressure distribution under the footing is determined from the load eccentricity:
- full contact — when the resultant stays inside the core of the base; a bilinear distribution, all corners compressed
- partial contact — when a corner or edge lifts off; the pressure concentrates on the remaining area, with a larger \(p_{max}\)
The lifted-corner zone, which has no simple formula, is solved exactly by the iterative Winkler solver. This distribution is the loading for the reinforcement design.
The ground itself is checked separately, for both \(\gamma_{G,sup}\) and \(\gamma_{G,inf}\) on the weight of the footing and soil:
- bearing, §6.5.2: \(V_d / A' \le q_{Rd}\), with the effective area \(A' = (L - 2|e_L|)(B - 2|e_B|)\). You enter \(q_{Rd}\), the design bearing resistance, for example from Annex D of EN 1997-1;
- eccentricity, §6.5.4: above \(1/3\) of the footing width the code requires special precautions, so the page declares the check not satisfied;
- sliding, §6.5.3: \(H_d \le V'_d \tan\delta_d\), in drained conditions, with the base friction taken from the \(\varphi'\) field and the design approach of the selected national annex. Passive resistance is neglected.
\(N\), \(M\) and \(F\) are design values. If \(N\) contains factored permanent loads, check sliding with its favourable value too. Seismic design to EN 1998-5 isn't covered by these checks.
Reinforcement and punching
From the pressure distribution follows the moment in the footing cantilever, at the column face, from which the bottom reinforcement of the footing is computed (EN 1992). Separately, the slab is checked for punching on the control perimeter around the column — the failure by which the column would punch through the footing. For footings, the specific rule §6.4.4(2) applies, with the soil reaction inside the perimeter subtracted from the punching force.
The deliverables
- The Word brief — a complete calculation report, with assumptions, formulas and checks, for the project documentation.
- The DXF drawing — the parametric drawing of the footing (formwork and reinforcement, several views), ready to open in AutoCAD.
Input data
- Geometry — the dimensions of the footing and the pedestal, the heights.
- The column — the section dimensions, the position.
- Loads — the axial force and the moments at the column base.
- The soil — the allowable pressure.
- Materials — the concrete class, the steel grade, the cover.