Code: SR EN 1992-1-1:2004 + NB:2008

Prestressed beam — Magnel diagram and cable zone

EN 1992-1-1 §5.10, §7.2, Table 7.1N · simply supported beam, uniform loads

Cross-section
Inverted T: top flange thickness 0. Haunches are ignored.CG · y_b = 612tendon · e_max = 522
Concrete
f_ck(t₀) and f_ctm(t₀) follow from §3.1.2, eqs. (3.1)–(3.4). Sets the Table 7.1N requirement for the bottom fibre: decompression or a tension limit.
Beam and loads
Self-weight g₀ = 25·A is computed automatically and is the only load at transfer. Δg and q act after transfer.
Prestressing
R follows from creep, shrinkage and strand relaxation (class 2, E_p = 195 GPa), iterated together with the force and the eccentricity. The exposed perimeter u is taken from the section.
Empty = the smallest number that covers P_min. The force used further is n·A_p·σ_pm0,max.
Tendon profile (parabolic)
e positive below the centroid. Empty = the lowest admissible at midspan and the closest to the centroid at the supports. Straight tendon: the same value in both.
▸ Fill in the data on the left and press Calculate
Tool information

What this page calculates

The page does the preliminary design of a simply supported prestressed beam. It looks for the prestressing force \(P_{m0}\) and the tendon eccentricity \(e\) that keep the concrete stresses within the EN 1992-1-1 limits, both at transfer and in service. It gives three results:

  • the Magnel diagram at midspan, with the minimum force and the eccentricity at which it is reached;
  • the number of strands, from the stress limit of the prestressing steel;
  • the cable zone, the band the tendon profile has to stay within along the whole beam.

The Magnel diagram turns stresses into straight lines

At the bottom and top fibres, the stress from the force \(k_P P\) at eccentricity \(e\) (positive below the centroid) and the moment \(M\) is:

\(\sigma_{bot} = -\frac{k_P P}{A} - \frac{k_P P\,e}{W_b} + \frac{M}{W_b} \qquad \sigma_{top} = -\frac{k_P P}{A} + \frac{k_P P\,e}{W_t} - \frac{M}{W_t}\)

Each stress limit looks nonlinear in \(P\) and \(e\). Gustave Magnel noticed that dividing the inequality by \(P\) makes it linear in \(e\) and \(1/P\). In the \((e,\ 1/P)\) plane every condition is a straight line, and the admissible solutions form a convex polygon. The highest vertex of the polygon gives the minimum force.

The page computes the polygon exactly, by clipping the physically possible rectangle with each half-plane in turn. It uses no sampling, and it does not assume in advance which line bounds the eccentricity from above and which from below. Many spreadsheets make that assumption, and it stops holding when the admissible tension is large compared with the moment, because the direction of the limit flips.

The Eurocode conditions

Classic textbooks use four conditions and a single service load. The Eurocode asks for more:

Situation Fibre Limit Force
Transfer, \(g_0\) bottom \(\sigma \ge -0.6\,f_{ck}(t_0)\) — §5.10.2.2(5) \(r_{sup}\,P_{m0}\)
Transfer, \(g_0\) top \(\sigma \le f_{ctm}(t_0)\) or 0 \(r_{sup}\,P_{m0}\)
Characteristic top \(\sigma \ge -0.6\,f_{ck}\) — §7.2(2) \(r_{inf}\,P_{m,\infty}\)
Quasi-permanent top \(\sigma \ge -0.45\,f_{ck}\) — §7.2(3) \(r_{inf}\,P_{m,\infty}\)
Frequent / quasi-permanent bottom decompression or \(f_{ctm}\) — Table 7.1N \(r_{inf}\,P_{m,\infty}\)

At transfer the large force is unfavourable, because it compresses the bottom fibre and puts the top fibre in tension. So \(r_{sup}\) applies there. In service the small force is unfavourable, so \(r_{inf}\) applies. The recommended values are 1.05/0.95 for pre-tensioning and 1.10/0.90 for post-tensioning (§5.10.9).

The requirement for the bottom fibre depends on the exposure class. XC2–XC4 require decompression under the quasi-permanent combination. XD and XS require decompression under the frequent combination. For X0 and XC1 the code allows 0.2 mm cracks, but the diagram assumes an uncracked section, so it limits the tension to \(f_{ctm}\).

Other conditions govern at the supports

At midspan the load moment offsets the effect of the prestress. Towards the supports the moment drops to zero, and if the profile rises above the centroid, the bottom fibre goes into tension and the top fibre into compression. These conditions do not show up in the midspan Magnel diagram. Without them the cable zone would come out too wide at the ends, on the unsafe side. That is why the page includes them explicitly (T3 and T4).

Number of strands

The initial force per strand is limited to \(\sigma_{pm0} \le \min(0.75\,f_{pk};\ 0.85\,f_{p0.1k})\) (§5.10.3). For Y1860S7 that is 1394 MPa, about 209 kN for a 150 mm² strand. The number of strands is \(P_{min}\) divided by the force per strand, rounded up. The actual force, \(n \cdot A_p \cdot \sigma_{pm0}\), is higher than the minimum, and the eccentricity interval is recalculated for it.

Prestress losses

The service conditions use the final force \(P_{m,\infty} = R \cdot P_{m0}\). The page can take the ratio \(R\) directly from the user, or it can calculate it to §5.10.6, eq. (5.46):

\(\Delta\sigma_{p,c+s+r} = \frac{\varepsilon_{cs} E_p + 0.8\,\Delta\sigma_{pr} + \frac{E_p}{E_{cm}}\,\varphi(t,t_0)\,\sigma_{c,QP}}{1 + \frac{E_p}{E_{cm}}\frac{A_p}{A_c}\left(1 + \frac{A_c}{I_c} z_{cp}^2\right)\left(1 + 0.8\,\varphi(t,t_0)\right)}\)

The inputs come from the same relations as the creep and shrinkage page, with two points to note:

  • the shrinkage that matters is only the part after transfer, \(\varepsilon_{cs}(\infty) - \varepsilon_{cs}(t_0)\). Shrinkage that happened before does not shorten the steel;
  • strand relaxation (class 2) is taken at 500,000 hours, as in §3.3.2(8). It grows very quickly with \(\mu = \sigma_{pi}/f_{pk}\): at \(0.75\,f_{pk}\) it is close to 5 %.

The calculation is circular: \(R\) changes the minimum force and the number of strands, and these feed back into the losses through \(A_p\) and \(\sigma_{c,QP}\). The page iterates until \(R\) stops changing. When the number of strands oscillates between two values, it keeps the larger losses.

Elastic shortening at transfer (§5.10.5.1) does not enter \(R\), because \(P_{m0}\) is already the force after it. It does show how hard the steel has to be stressed: \(\sigma_{p0} = \sigma_{pm0} + \Delta\sigma_{el}\) must stay below \(\sigma_{p,max}\). For post-tensioning with \(n\) tendons stressed one after another, the average loss is \((n-1)/2n\) of the pre-tensioning value.