Braced excavation step by step — a staged finite element model and its results
Published 19 October 2026 · 🇷🇴 Română
In short: A 4 m excavation with a concrete wall and a strut, modelled stage by stage with finite elements in the browser: how the model is built, why the K0 initial state matters, what displacements and forces come out (27.2 mm, 20.3 kNm/m, 25.4 kN/m).
The problem
A 4 m deep excavation, supported by a concrete wall embedded in the ground and a strut (a compression member) 1 m below the surface. The design questions are the usual ones: how far does the ground behind the wall move, how much bending does the wall take, and what force ends up in the strut.
A hand calculation (Rankine pressures on a beam) answers the second question only roughly and the first one not at all: displacements depend on the stiffness of the ground, on the order of excavation and on when the strut goes in. That is why an excavation is modelled in stages, with finite elements. The example below opens ready-made in the JointLib geotechnical model and runs in a few tens of seconds.
The model
| Item | Data |
|---|---|
| Soil | E = 20 MPa, ν = 0.3, c′ = 20 kPa, φ′ = 30°, ψ = 0, γ = 18 kN/m³, Mohr-Coulomb |
| Excavation | 4 m deep, 8 m half-width (half the pit is modelled, with symmetry) |
| Wall | concrete, 0.6 m thick, 7 m long (3 m embedment below formation), E = 30 GPa |
| Strut | at −1 m, E = 200 GPa, A = 0.02 m² per metre, connected at its ends only |
| Mesh | 1.2 m elements, refined to 0.4 m around the wall toe |
| Boundaries | base fixed in both directions, vertical sides fixed horizontally |
The stages
- Initial state (K0). The stresses in the ground before any work: vertical from self-weight, horizontal K0 = 1 − sin φ′ = 0.50 · σ′v.
- Wall installation. The wall is activated; displacements are measured from zero from here on.
- Eight excavation lifts of 0.5 m. After the second lift (at −1 m) the strut is installed.
Stage 1 deserves a word, because it is a classic trap. To generate the initial stresses, the solver loads the ground with its own weight, and the ground "settles": here by almost 65 mm. That settlement is not real. The ground has been there for thousands of years and does not settle under its own weight any more. That is why displacements are measured from wall installation. Since October 2026 JointLib does this automatically: the K0 stage itself is shown with zero displacements (the initial state), and the stage right after it starts from zero, so the fictitious settlement never reaches the wall displacements, even when the user forgets the reset box.
Results at the end of excavation
| Quantity | Value |
|---|---|
| Maximum ground displacement since wall installation | 27.2 mm |
| Maximum bending moment in the wall | 20.3 kNm/m |
| Maximum axial force in the wall | 61.5 kN/m (compression) |
| Strut force | 25.4 kN/m (compression) |
Every stage from installation onwards uses the same colour scale (0–27.2 mm), so they can be compared directly: the deformed zone grows from behind the wall towards the formation level, and the strut limits the movement of the wall head once it is in place.
How to reproduce it
Open the geotechnical model with the example preloaded and press Run. You need a free account; the first 3 runs of every Studio program are free, no card needed. From the results you can download the calculation report as a Word document.
How the solver was checked (391 automated checks, against analytical solutions and published benchmarks) is described on the solver page.