391 automated checks for the geotechnical FEM solver — the complete census
Published 8 September 2026 · 🇷🇴 Română
In short: We publish all 391 automated checks of the geotechnical FEM solver — 74 against external sources (published benchmarks, papers, a real laboratory test), 101 closed forms of our own, 216 invariances and guards — with the full table and the stories behind it.
Why we publish this
The easiest way to sell a geotechnical solver is to say "it's validated" and move on. We don't, for practical reasons rather than moral ones: an engineer choosing analysis software doesn't read the claim, they look for where it breaks. A claim they can take apart in five minutes does more harm than ten more modest claims that survive scrutiny.
That is why we publish the complete census of our regression suite: 391 automated checks, of which 74 are compared against a published external source — published benchmarks, technical papers, a real laboratory test. The other 317 are not "less important" — they are a different kind of check, and we explain below why they matter just as much.
Nothing in this article is a comparison with the results of another program. We compared against published benchmarks — constitutive laws written as equations, applied to a single material point, not complete boundary value problems. The difference matters, and a careful engineer notices it immediately if we ignore it.
The census — what rests on what
The regression run of 2026-09-08 executed 33 test benches, with 388 checks passed out of 391 (3 failures, all isolated to a single non-reproducible case, explained below). Each of the 391 was classified, check by check, into three categories:
| category | checks | share |
|---|---|---|
| E — published external oracle | 74 | 18.9 % |
| F — closed form / exact identity, written by us | 101 | 25.8 % |
| I — invariance, negative control, guard | 216 | 55.2 % |
What each category means:
- E (74 checks) — the solver result is compared directly with a number published by someone else: a value from a published benchmark, a paper, a design code, or a real laboratory test.
- F (101 checks) — the result is compared with a closed form or an exact mathematical identity, written by us from the equations the material law declares it implements. The formula is published, but the comparison is with ourselves, not with a third party.
- I (216 checks) — invariances, negative controls and guards: the result does not depend on mesh refinement, does not depend on the size of the domain, two independent paths through the code give the same number, a disabled parameter produces exactly the expected behaviour.
Why invariances matter, not only comparisons
It is tempting to read the 55.2% share of invariances as a sign of weakness — "only 74 of 391 are real validation". That is not right, and it is worth explaining why.
A comparison with a table can come out well by chance. If the factor of safety computed for a slope changed when you doubled the model domain — a classic numerical artefact — its agreement with the Bishop method on the chosen case could be coincidence, not correctness. A separately verified invariance — "the factor of safety does not change when the domain is doubled" — closes exactly that possibility. It catches whole classes of defects that a comparison with a table cannot see at all: a domain that is too small, a wrong boundary condition, a discretisation that affects the physical result.
Invariances make the comparisons credible; they do not replace them. E + F = 175 of 391 (44.8%) are checks where a computed number is compared with another number known in advance. The rest check properties the result must have regardless of that number — and without them, the 175 would be less believable, not equally so.
The 74 checks against external sources
These are the published sources the solver was compared against, with the number of checks for each and the concrete figures available from the regression run:
| source | checks | what was measured |
|---|---|---|
| Published benchmarks for Hardening Soil, HS-small and Soft Soil Creep (Schanz et al. 1999; Benz 2007; Vermeer & Neher 1999) | 29 | Hardening Soil and HS-small on Hostun sand (real laboratory), drained/undrained HS on three sands, Soft Soil Creep in oedometer and triaxial at different strain rates |
| Schweiger (2002) — the Berlin excavation | 6 | the Mohr-Coulomb / Hardening Soil hierarchy, settlement from dewatering, the wall displacement band |
| Yu & Kaufmann (RevEngSTM) | 6 | six published strut-and-tie models, reproduced with our program |
| Published reference example — consolidation with creep | 5 | 1D consolidation with secondary compression, up to 1000 years |
| Prandtl–Reissner (closed form) | 6 | bearing capacity \(q_u = (2+\pi)c_u\), along four different paths through the code |
| EN 1997-1, Annex D | 3 | the factors \(N_q\), \(N_c\), \(N_\gamma\) at \(\varphi' = 20°, 30°, 40°\) |
| Rankine, Coulomb, Caquot-Kérisel | 3 | active earth pressure at three friction angles, the \(K_p\) table |
| Terzaghi — 1D consolidation | 3 | the exact series \(U(T_v)\), along two paths through the code |
| Interface shear test (published benchmark) | 3 | \(\tau/\sigma_n = \tan\delta\) after mobilisation, at three angles |
| FHWA-NHI-10-024 — reinforced soil | 3 | distribution of the tensile force over the layers, Figure 4-10 |
| Rudnicki & Rice — localisation | 3 | loss of ellipticity before the peak, under non-associated flow |
| Simplified Bishop (method of slices) | 2 | factor of safety on a homogeneous and a layered slope |
| EN 1997 — hydraulic heave | 1 | critical gradient under upward flow |
| Taylor — stability number | 1 | stability number for a vertical slope |
| Total | 74 |
The concrete figures, check by check
For those who want the exact number, not only the source — this is the full selection of numerical comparisons documented in the regression run, with the deviation from the reference:
Soft Soil Creep (a self-checking oracle: the very constants given as input are recovered from the curve):
| quantity | recovered from the curve | given as input | deviation |
|---|---|---|---|
| \(\lambda^*\), from the primary slope 80→640 kPa | 0.0998 | 0.1000 | −0.2 % |
| \(\mu^*\), from secondary creep | 0.00487 | 0.00500 | −2.6 % |
| vertical POP 433 kPa → isotropic pressure \(P_p\) | 374.1 kPa | 373 kPa | +0.3 % |
§16.4, effect of strain rate on undrained strength (Haney clay):
| rate ratio | measured q | theory (closed form) | deviation |
|---|---|---|---|
| ×159.4 | 1.2163 | 1.2560 | −3.2 % |
| ×7.3 | 1.0789 | 1.0937 | −1.4 % |
| ×1169.5 | 1.3122 | 1.3737 | −4.5 % |
§16.1, drained Hardening Soil plateau, three sands (closed form \(q_f = 2\sigma_3\sin\varphi/(1-\sin\varphi)\)):
| sand | measured \(q_{max}\) | closed form | deviation |
|---|---|---|---|
| loose, φ=30° | 200.08 kPa | 200.00 kPa | +0.04 % |
| medium, φ=35° | 269.55 kPa | 269.02 kPa | +0.20 % |
| dense, φ=40° | 362.07 kPa | 359.89 kPa | +0.60 % |
§16.2, Hostun sand — real laboratory tests (Prof. J. Desrues, Université Joseph Fourier, Grenoble), drained triaxial at σ₃=300 kPa:
| sand | measured \(q_{max}\) | closed form | deviation |
|---|---|---|---|
| loose, φ=34° | 761.14 kPa | 761.14 kPa | +0.00 % |
| dense, φ=41° | 1144.49 kPa | 1144.49 kPa | +0.00 % |
The same Hostun sands, oedometer at 100 kPa (recovery from the \(E_{oed}\) formula):
| sand | measured | table | deviation |
|---|---|---|---|
| loose | 15,947 kPa | 16,000 kPa | −0.3 % |
| dense | 29,538 kPa | 29,600 kPa | −0.2 % |
§16.3, HS-small on Hostun — stiffness \(G_0\) recovered at three confining pressures (all below 0.01 %):
| sand | σ₃=100 | σ₃=300 | σ₃=600 |
|---|---|---|---|
| loose | 69,999 / 70,000 | 142,962 / 142,964 | 224,332 / 224,335 |
| dense | 112,499 / 112,500 | 194,855 / 194,856 | 275,566 / 275,568 |
γ₀.₇ — the strain at which the secant modulus drops to 0.722·G₀:
| sand | measured ratio | definition | deviation |
|---|---|---|---|
| loose | 0.7217 | 0.7220 | 0.379 % |
| dense | 0.7211 | 0.7220 | 0.159 % |
Berlin (Schweiger 2002) — corrected on 2026-10-19. The pair −11.72 / −33.01 mm originally published here came from a single, unreproduced run and has been withdrawn. After the fix of 24.09 (see the correction under "The problem with no smooth solution"), the complete model — 13 stages, excavation down to 16.8 m, with the dewatering and the unit weights of the source — gives the same figures twice. With the automatic displacement reset after the K0 stage (19.10) and with the wall activated after it, together with the dewatering (26.10), Mohr-Coulomb heaves the ground behind the wall (+55.5 mm, the average over the first 30 m), while Hardening Soil settles it (−16.0 mm, maximum −20.8 mm). The wall displacement with Hardening Soil is 29.0 mm, i.e. 0.172 % of the depth, within the band measured on similar excavations (0.07…0.40 %). The settlement from dewatering comes out at 12.7 mm, between the "approximately 1 cm" and "approximately 3 cm" of the published reproductions. The difference between the laws is precisely the behaviour that made this benchmark famous.
Bearing capacity — FEM vs Prandtl-Reissner:
| case | FEM | Prandtl | deviation |
|---|---|---|---|
| undrained, φ=0 | 110.90 kPa | 102.83 kPa | +7.84 % |
| drained, φ=20° | 322.00 kPa | 296.69 kPa | +8.53 % |
| \(q_u\) proportional to c | ratio 1.99620 | 2 | −0.19 % |
| global equilibrium | — | — | 4.43e-15 |
EN 1997-1, Annex D — bearing capacity factors:
| quantity | computed | reference |
|---|---|---|
| \(N_q\), φ=20° | 6.3994 | 6.399 |
| \(N_c\), φ=20° | 14.8347 | 14.835 |
| \(N_\gamma\), φ=20° | 3.9304 | 3.93 |
| \(N_q\), φ=30° | 18.4011 | 18.401 |
| \(N_c\), φ=30° | 30.1396 | 30.14 |
| \(N_\gamma\), φ=30° | 20.0931 | 20.093 |
| \(N_q\), φ=40° | 64.1952 | 64.195 |
| \(N_c\), φ=40° | 75.3131 | 75.313 |
| \(N_\gamma\), φ=40° | 106.0541 | 106.054 |
Rankine, Coulomb, Caquot-Kérisel — active earth pressure coefficient:
| case | FEM | reference | deviation |
|---|---|---|---|
| \(K_a\), smooth wall, φ=25° | 0.4059 | 0.4059 | — |
| \(K_a\), smooth wall, φ=30° | 0.3332 | 0.3333 | −0.03 % |
| \(K_a\), smooth wall, φ=35° | 0.2708 | 0.2710 | −0.07 % |
| \(K_a\), Coulomb δ=10° | 0.3045 | 0.3038 | +0.2 % |
| \(K_a\), Coulomb δ=20° | 0.2825 | 0.2794 | +1.1 % |
Terzaghi, 1D consolidation — degree of consolidation \(U(T_v)\):
| \(T_v\) | measured | theory |
|---|---|---|
| 0.05 | 0.2539 | 0.2523 |
| 0.10 | 0.3597 | 0.3568 |
| 0.20 | 0.5081 | 0.5041 |
Maximum deviation over the whole range \(T_v\) = 0.05…1.0: 0.0042. Ratio of double-sided to single-sided drainage: 4.02 against the theoretical 4.
Coulomb contact, interface shear:
| δ | measured \(V/N\) | \(\tan\delta\) | deviation |
|---|---|---|---|
| 15° | 0.2678 | 0.2679 | −0.1 % |
| 20° | 0.3637 | 0.3640 | −0.1 % |
| 25° | 0.4661 | 0.4663 | −0.1 % |
FHWA-NHI-10-024, §4.4.7 — geogrid-reinforced soil, distribution of the tensile force over the layers:
| layer | z [m] | measured T [kN/m] | FHWA T [kN/m] | ratio |
|---|---|---|---|---|
| 1 | 1.50 | 7.20 | 8.76 | 0.82 |
| 2 | 2.50 | 11.55 | 14.59 | 0.79 |
| 3 | 3.50 | 15.32 | 20.43 | 0.75 |
| 4 | 4.50 | 21.57 | 26.27 | 0.82 |
| 5 | 5.50 | 27.81 | 32.11 | 0.87 |
| Σ | 86.43 | 105.08 | 0.823 |
The ratio is constant with depth — slope·H/mean = 0.088, max/min scatter = 1.16 over layers 1…5 — which means the model reproduces the very discriminating statement of Figure 4-10: for geosynthetic reinforcement the ratio stays constant with depth (unlike metallic strips, where it would drop from 1.7 to 1.2). The level of 0.823 comes out below the simplified method, the documented direction, because the method is conservative by construction.
EN 1997 — hydraulic heave: the critical gradient \(i_{crit} = \gamma'/\gamma_w\) is recovered exactly from the solver.
For Yu & Kaufmann (strut-and-tie models) and Rudnicki & Rice (loss of ellipticity), the regression run reports the comparisons as passed (6/6, and checks along four paths through the code, respectively), without a single representative deviation figure that could be published separately — the comparison is one of shape/behaviour, not of a decimal.
The stories behind the figures
A table of deviations shows that things work. The stories below show how we found out, and why each defect was hard to find — they are real, with exact figures, not rounded anecdotes.
The contact that wasn't there. Coulomb's law for the wall–soil interface was correct, but the contact elements generated automatically from the model schema had their normal flipped — compression was read as tension, cut off to zero, and the contact became inert. Not "softer": no stress at all, with the faces passing through each other. Measured: traction (0, 0) kPa and 3.0 mm penetration, against (−100, 0) kPa and 0.025 mm after the fix. The defect stayed hidden because an elastic contact is symmetric in sign and worked perfectly — it took two days to track down.
The dead bench that showed green — twice. A validation test failed on an encoding error in a simple print, before even the first check — so it automatically reported "zero failures" and looked identical to a test that genuinely passes. We added a guard: the regression script also counts the process exit code, not only how many failures were printed.
That guard turned out to be insufficient at the first opportunity. In the full regression run of 8 September, a new bench ran for 370 seconds, exited with code 0 and reported zero checks — because it was written with a different marker style from the one the counter was looking for. Its 7 checks had passed; nobody was simply seeing them. Exactly the pattern the guard had been written against, slipping past it.
The fix was not just "learn the second marker style too" — that would have left the trap open for a third. The general rule is now: any bench that exits with code 0 but reports zero checks is flagged explicitly. A test that cannot fail is not a test; and a test you don't count is not even a test.
The creep deficit that wasn't there. For days we chased a "3.3 times too little" on the secondary slope of a Soft Soil Creep model. It was neither the law nor the solver — it was the loading protocol. In this model, plastic strain appears only through creep, so the theoretical behaviour appears only when the loading is slow enough for creep to keep up. That is why the published benchmark applies one load step per day — not as a convenience, but as the condition under which the result means anything.
Five wrong explanations for a single problem. A geogrid-reinforced soil bench stayed open for three working sessions. Grids placed too close to the wall gave internal forces −97% off the expected value. A comparison between two successive runs showed that the reinforcement changed the very quantity being compared. A base fixed along its full length took the whole earth pressure by itself, masking the result. A wall with interfaces tied the end of the grid to its twin in the soil — checked node by node. And the hardest to see: the missing tributary area — without a defined face on each panel, the model converges nicely and gives a qualitatively correct shape, but at 40% of the real level. Only the fifth set-up — discontinuous panels, one per layer — produced the correct result, the one in the table above.
The problem with no smooth solution. The Berlin case (Schweiger 2002), on a refined mesh, is not reproducible: two runs of the same code, on the same day, gave 9 of 9 checks passed and 6 of 9, respectively. It is not a solver defect — beyond about 70% of the mobilised strength the mathematical problem loses ellipticity: strain can jump across a surface, a shear band forms, and the smooth solution the numerical algorithm is looking for simply no longer exists in that regime. There is a separate test that checks exactly this phenomenon (Rudnicki-Rice). It is the reason why the only publishable figure from Berlin is the difference in behaviour between the material laws, not a displacement value from the fine mesh — knowing when you may not believe the result is part of the solver, not an excuse.
Correction (2026-10-19): the explanation above was wrong. The real cause came to light on 24 September. The material law, compiled separately, ran on several threads, and some of its working variables sat in memory shared by all threads: the integration points overwrote each other's values. Two identical runs differed by 1.7 mm (8–13 %) already in the initial state; after the fix, by 6·10⁻¹⁵ m, and the complete Berlin model passes all stages, twice with the same figures. The single-material-point tests ran on one thread and could not see the defect. Loss of ellipticity is a real phenomenon and has its own separate test, but it was not what explained the Berlin results. We leave the original story here because it shows how easy it is to find a plausible physical explanation for a coding defect.
The elements that were tried and failed. Two alternative finite element types were tested and deliberately abandoned: one gave −40% on a bearing capacity test and +26.8% on an elastic test where another element was exact; the other gave +141% or zero, depending on the case. Their geometry was correct — they integrated their own volume exactly — but the stiffness came out 27% wrong. An element that computes its area correctly can get its stiffness completely wrong, and the difference only shows when you test it directly.
You can reproduce it yourself
All the figures above come from the full regression run of the test suite, not from hand-picked examples. The input data of each benchmark — the source down to page and table, the complete material parameters — are documented separately, and the check-by-check classification is generated by an auditable script, not written by hand.
If you want to see the geotechnical FEM solver at work, not only its validation figures, the model is available live at /en/bim/geotechnical-model.